user1asd34123asdsa

About user1asd34123asdsa

This author has not yet filled in any details.
So far user1asd34123asdsa has created 177 blog entries.

Feasibility of atrial fibrillation ablation via right internal jugular access using a lattice-tip pulsed field ablation system in the presence of inferior vena cava aplasia: first clinical experience

2026-11-18T22:59:11+00:00

PubMed: Gerontitis D, et al. Eur Heart J Case Rep. 2026 Jul 17;10(7):ytag541. e-Link Case description A 75-year-old male with symptomatic paroxysmal atrial fibrillation and underlying sinus bradycardia was scheduled for pulmonary vein isolation. Initial femoral venous access revealed complete inferior vena cava (IVC) aplasia, with venous return diverted via a dilated azygous vein into [...]

Feasibility of atrial fibrillation ablation via right internal jugular access using a lattice-tip pulsed field ablation system in the presence of inferior vena cava aplasia: first clinical experience 2026-11-18T22:59:11+00:00

Successful isolation of arrhythmogenic superior vena cava via balloon-in-basket pulsed field ablation: Overcoming phrenic nerve proximity

2026-11-18T22:59:00+00:00

PubMed: Gerontitis D, et al. HeartRhythm Case Rep. 2026 Jun 12;12(8):878-882. e-Link Introduction Atrial tachycardia (AT) originating from non–pulmonary vein (PV) sources remains a significant challenge for clinical electrophysiologists. Among these sites, the superior vena cava (SVC) is 1 of the most common locations for focal triggers that can initiate or maintain atrial arrhythmias, including [...]

Successful isolation of arrhythmogenic superior vena cava via balloon-in-basket pulsed field ablation: Overcoming phrenic nerve proximity 2026-11-18T22:59:00+00:00

Medtronic Affera™ System: Advantages in Atrial Fibrillation Ablation

2026-11-18T22:49:03+00:00

Atrial fibrillation (AF) ablation requires the creation of continuous, transmural, and permanent lesions while simultaneously minimizing the risk of complications. The Medtronic Affera™ system, combined with the Sphere-9™ catheter, constitutes an integrated platform that addresses these challenges. By unifying high-definition three-dimensional electroanatomical mapping (HD Mapping) and on-demand dual-energy delivery (RF and PFA), the system offers [...]

Medtronic Affera™ System: Advantages in Atrial Fibrillation Ablation 2026-11-18T22:49:03+00:00

Left Atrial Appendage Closure: Will It Replace Anticoagulants?

2026-11-18T22:48:52+00:00

Introduction The prevention of ischemic stroke in patients with atrial fibrillation (AF) is fundamentally based on direct oral anticoagulants (DOACs), which have radically transformed the therapeutic landscape. Despite their efficacy, bleeding risk remains the primary limiting factor for their long-term use. Percutaneous left atrial appendage closure (LAAC) was developed as a focused, non-pharmacological solution, grounded [...]

Left Atrial Appendage Closure: Will It Replace Anticoagulants? 2026-11-18T22:48:52+00:00

Pulsed Field Ablation: Will It Define the Future of Atrial Fibrillation Treatment?

2026-11-18T23:21:38+00:00

Perhaps one of the questions that will concern us in the future is not so much whether pulsed field ablation (PFA) represents the future of atrial fibrillation (AF) ablation—as this is already an established reality and the momentum is irreversible—but rather whether it will redefine the broader management of the disease. The real crux of [...]

Pulsed Field Ablation: Will It Define the Future of Atrial Fibrillation Treatment? 2026-11-18T23:21:38+00:00

Paradigm Shift: Defibrillator Leads Designed for LBBAP (Medtronic OmniaSecure™)

2026-11-18T22:48:37+00:00

A major historical limitation of conduction system pacing (CSP) has been the inability to deliver physiological pacing directly through a defibrillation lead. Patients with an indication for an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) who required left bundle branch area pacing (LBBAP) previously necessitated a "two-lead" approach. This involved positioning a specialized, [...]

Paradigm Shift: Defibrillator Leads Designed for LBBAP (Medtronic OmniaSecure™) 2026-11-18T22:48:37+00:00

Atrial Fibrillation Ablation in Heart Failure: YES. Because that is where it is needed most!

2026-11-18T22:48:41+00:00

The coexistence of atrial fibrillation (AF) and heart failure (HF) represents one of the most frequent and dangerous combinations in modern cardiology, exponentially multiplying patient morbidity and mortality. Their relationship is bidirectional and pathophysiologically intertwined: AF exacerbates HF through rapid and irregular ventricular rates that reduce diastolic filling time and cardiac output, frequently leading to [...]

Atrial Fibrillation Ablation in Heart Failure: YES. Because that is where it is needed most! 2026-11-18T22:48:41+00:00

Left Bundle Branch Area Pacing (LBBAP): Definition and Latest Advancements in Conduction System Pacing

2026-11-18T23:21:25+00:00

Introduction Conventional right ventricular pacing (RVP) is unequivocally associated with a 15–20% incidence of pacing-induced cardiomyopathy, a consequence of the resulting electromechanical dyssynchrony. Modern electrophysiology is undergoing a definitive paradigm shift toward conduction system pacing (CSP). This modality directly stimulates the intrinsic cardiac conduction system, with left bundle branch area pacing (LBBAP) currently representing the [...]

Left Bundle Branch Area Pacing (LBBAP): Definition and Latest Advancements in Conduction System Pacing 2026-11-18T23:21:25+00:00

Successful Radiofrequency Ablation of Paroxysmal Atrial Tachycardia from the Para-Hisian Region via the Non-Coronary Cusp of Valsalva

2026-11-18T22:47:30+00:00

Introduction Atrial tachycardias localized in the para-Hisian region represent a distinct clinical entity that demands precise differential diagnosis from atrioventricular nodal reentrant tachycardia (AVNRT) or septal accessory pathways. Direct targeting of the margins of the His bundle region from either the right or left atrium carries a significant risk of mechanical or thermal injury to [...]

Successful Radiofrequency Ablation of Paroxysmal Atrial Tachycardia from the Para-Hisian Region via the Non-Coronary Cusp of Valsalva 2026-11-18T22:47:30+00:00

Successful Ablation of a Septal Biatrial Tachycardia and a Perimitral Circuit Using a Lattice-Tip Catheter Following Prior Pulmonary Vein Isolation

2026-11-18T22:47:34+00:00

Introduction Atrial tachycardias (AT) after atrial fibrillation (AF) ablation procedures represent a frequent clinical challenge [1]. The emergence of complex biatrial circuits requires detailed three-dimensional electroanatomical mapping. This case highlights the clinical value of modern, large footprint lattice-tip catheters. Case Presentation A 68-year-old male with a history of paroxysmal atrial fibrillation underwent an ablation procedure [...]

Successful Ablation of a Septal Biatrial Tachycardia and a Perimitral Circuit Using a Lattice-Tip Catheter Following Prior Pulmonary Vein Isolation 2026-11-18T22:47:34+00:00