Your biventricular system implantation procedure was completed successfully. This device—either a biventricular pacemaker (CRT-P) or, more commonly, a biventricular defibrillator (CRT-D)—delivers cardiac resynchronization therapy. Utilizing three separate leads, it coordinates the simultaneous contraction of your left and right ventricles to significantly improve your heart’s pumping efficiency. If your device is a CRT-D, it provides the additional benefit of protecting your heart from dangerous, rapid arrhythmias. Your recovery phase begins now. To ensure proper wound healing and the secure stabilization of all three leads within your heart, it is critical that you strictly follow these instructions.
1. Wound Care (Chest Area)
- Surgical Site: The incision is approximately 4-5 centimeters long (slightly larger than a standard pacemaker incision due to the physical size of the device) and is located in the upper chest area, just below the collarbone (typically on the left side).
- Showering: You may shower normally starting the day after your procedure, only if a special waterproof dressing has been applied. If the dressing is not waterproof, keep the area completely dry until your first scheduled dressing change.
- Swimming (Ocean & Pools) – Warning: Unlike showering, swimming in the sea or a pool and complete submersion in water are strictly prohibited for the first 1 to 1.5 months. The wound must heal completely, both externally and internally, to eliminate any risk of infection. Furthermore, the rigorous motion of swimming can easily displace the device leads.
- Dressing Changes & Sutures: The dressing will be removed or changed according to your medical team’s instructions (usually after 48 hours). If absorbable sutures were used (which is the most common practice at our Center), no physical removal is necessary. If there are non-absorbable stitches that need to be removed, this is typically done within 10-12 days.
- Local Symptoms (No cause for concern): It is expected and entirely normal to feel a mild "tugging" sensation or to notice a bruise developing around the wound and extending toward the upper arm. This is a standard part of the skin’s natural healing process and will gradually resolve on its own within 2-3 weeks.
- Clothing: Opt for loose, comfortable cotton clothing (such as button-down shirts) to avoid putting unwanted pressure on the device area and to make dressing easy without needing to raise your arm.
2. Arm Movement Restrictions (Very Important)
For the first 4 to 6 weeks, the three leads connecting your biventricular system to your heart (located in the right atrium, right ventricle, and the coronary sinus to reach the left ventricle) require sufficient time to secure themselves firmly into place. On the side where the device was implanted, these leads are anchored near the muscle that moves your arm. Severe or abrupt movements with this arm can pull on the leads and cause them to shift (lead displacement), which would require an entirely new surgical procedure to reposition them. Strictly adhere to the following rules:
- No lifting the arm: Do not raise your arm above shoulder height (e.g., do not reach for items on high shelves or brush your hair using that hand).
- No reaching backward: Avoid extending your arm forcefully or abruptly behind your back.
- No pushing or bearing weight: Do not use this specific arm to push yourself up when getting out of bed or rising from a chair.
- No weight loading: Do not allow this arm to support the physical weight of your torso.
3. Physical Activity & Daily Routine
- Lifting Weights: Do not lift any weight exceeding 3-5 kilograms for the first month (avoid heavy grocery bags, luggage, or lifting children). This restriction applies primarily to the arm on the side of the implanted biventricular device.
- Daily Use: You can use your arm normally for low-level, simple daily movements, such as eating, writing, or brushing your teeth. Complete immobilization of the arm is forbidden, as it can quickly cause severe shoulder stiffness (known as "frozen shoulder").
- Exercise & Swimming: Avoid strenuous physical exercise, running, golf, or tennis for at least 4-6 weeks. Swimming is completely prohibited during this 1 to 1.5-month period until all leads have fully stabilized.
- Driving: Do not drive until your attending physician gives you explicit permission. With biventricular systems (especially if they include a CRT-D defibrillator), driving restrictions are strict and depend directly on your personal history of heart failure and arrhythmias.
- Seatbelt Use: When traveling by car (as a passenger, or later as a driver), the seatbelt will inevitably cross directly over your device. If you feel uncomfortable pressure or friction against the wound, it is highly recommended to use a special soft seatbelt padding cushion (soft pad), which you can easily purchase from automotive supply stores.
4. Medications & Pain Relief
- Pain Management: For localized pain or discomfort during the first few days, you may take paracetamol (such as Depon or Panadol).
- Cardiology Medications: Your heart failure medications (such as SGLT2 inhibitors, ARNI/ACE inhibitors, beta-blockers, and aldosterone antagonists), as well as Aspirin, anticoagulants, or antiarrhythmic drugs, must be continued, modified, or resumed always and exclusively under your doctor’s specific guidance. These medications form the cornerstone of your treatment alongside your biventricular system.
5. Living with a Biventricular System & Electromagnetic Safety
Modern cardiac devices feature exceptional built-in shielding, but for your safety, please observe the following precautions:
- Cell Phones: You can use your mobile phone on either ear; it will not interfere with the device’s function. The only recommendation is to avoid placing your cell phone in a breast pocket directly over the device to completely eliminate any chance of electromagnetic interference.
- Household Appliances: Microwave ovens, televisions, computers, and conventional cooking stoves are completely safe. Appliances with exceptionally strong internal magnets or induction cooktops should be kept at a safe distance of at least 15-30 centimeters.
- Security Detectors & Airport Screenings: Walk through retail store security gates at a normal pace without lingering between them. At airports, immediately present your Device Identification Card to the security personnel. Once informed, security staff will guide you around the metal detector gate to perform a manual pat-down check. They will actively avoid passing the hand-held magnetic screening wand directly over your chest area.
- Medical Tests & MRI Scans: Always inform every doctor or dentist you visit that you have an implanted biventricular system. Magnetic Resonance Imaging (MRI) is safe with most modern systems, but it strictly requires special programming (MRI mode) of the device immediately before and after the scan by a specialized technician from the manufacturing company. If the device enters an MRI machine without this pre-programming, its operations may lock up or the critical synchronization of your heart may be disrupted.
- Household Electrical Leaks (Precaution): Particular caution is required in older properties that lack a safety residual current device (RCD / safety relay) in the main electrical panel. This precaution applies primarily to patients whose biventricular system includes a defibrillator (CRT-D). In such cases, if you touch a faulty electrical appliance with an active current leak, the device might misinterpret the external electrical field as an episode of ventricular tachycardia and deliver an accidental, unnecessary shock (defibrillation). For this reason, if your home’s wiring is old, an inspection by a professional electrician is strongly recommended.
- Physical Therapy & Electrical Currents: Inform your physical therapist that you have a biventricular system. Diathermy (shortwave/microwave therapy) and TENS treatments (transcutaneous electrical nerve stimulation) are strictly prohibited around the chest and shoulder area, as these currents can disrupt device function. Standard manual massages, mobility exercises, therapeutic ultrasound, and laser therapies can be performed normally, provided they are not applied directly over the device.
6. Follow-Up & Medical Monitoring
- Device Identification Card: Upon your discharge, you will be given the official Device Identification Card from the manufacturing company. You must always carry this card with you in your wallet.
- First Appointment: Your first follow-up appointment to check the surgical wound will be scheduled a few days after the procedure or at the one-month mark, depending on your physician’s instructions.
- First Device Check (Interrogation): The initial electronic check of the device takes place around 1 month post-surgery. During this check, the physician evaluates the proper function of all three leads and the remaining battery longevity. Most importantly, they assess the biventricular pacing percentage (biventricular pacing %), which needs to be as close to 100% as possible to ensure maximum clinical improvement of your heart failure.
- Subsequent Scheduled Checks: Following the completion of the initial evaluation, all subsequent routine follow-up checks for your device will be conducted based on your attending physician’s instructions and the specific appointment scheduled each time. This applies equally to all three types of cardiac devices (pacemakers, defibrillators, and biventricular systems).
- How the Check is Performed (Non-Invasive): This evaluation is entirely non-invasive and painless. It is performed in an office setting simply by placing a special external programming wand over the skin where your device is located, which wirelessly reads all data within a few minutes.
- Smartwatch Use: You may use your smartwatch to track your heart rate. The device is programmed to keep your resting heart rate above a specific, safe baseline limit.
7. Emergency Instructions in Case of Shock Activation (For CRT-D Systems)
If your biventricular system includes a defibrillator (CRT-D) and delivers a shock (which feels like a sudden, powerful blow to the chest), remain calm and immediately follow this emergency protocol:
- If you receive ONE (1) single shock AND you feel perfectly fine afterward:
- Sit or lie down immediately for your safety.
- Ask a family member or someone close to you to stay by your side.
- Contact our medical team or your cardiologist within 24 hours to schedule a device interrogation check.
- If you receive MULTIPLE shocks (two or more) OR if you feel sick, dizzy, or short of breath after a single shock:
- This is an acute medical emergency (Electrical Storm or acute cardiac decompensation).
- Call emergency services immediately (166 / Local Emergency Number) for immediate ambulance transport to the nearest hospital.
- Under no circumstances should you attempt to drive yourself to the hospital.
- If you feel dizzy, faint, or lose consciousness:
- Your relatives or bystanders must be informed in advance: If you lose consciousness and the device does not successfully terminate the arrhythmia, they must call emergency services immediately and begin CPR if required.
8. When to Contact Your Doctor
Implantation of a biventricular system is generally a very safe procedure. However, you should contact us or proceed to the hospital immediately if you experience any of the following symptoms:
- Activation of Shock Therapy (CRT-D): Any episode where a shock is delivered, strictly following the safety protocol outlined in Section 7.
- Wound Problems (Local Infection or Hematoma): If the area develops severe and increasing swelling, becomes very red or hot to the touch, if the incision opens, or if fluid/pus drains from it. Mild localized hematomas (bruising with swelling) will reabsorb on their own, but the medical team must evaluate them to guide you appropriately (you can send a photo of the wound via your mobile phone).
- Worsening Heart Failure Symptoms: If you notice a sudden, unexplained weight gain (more than 1.5-2 kilograms within 2-3 days due to fluid retention), swelling in your ankles or legs (peripheral edema), increasing fatigue with minimal exertion, or the sudden need to sleep with additional pillows to breathe comfortably (orthopnea). These signs indicate that the system may require specialized electronic adjustments to its synchronization programming.
- Return of Fainting Symptoms: Severe dizziness, lightheadedness, a feeling that you are about to pass out, or an actual fainting episode (indicative of potential lead displacement).
- Local Diaphragmatic Nerve Irritation: If you develop persistent, continuous hiccups or rhythmic twitching in your chest or diaphragm that synchronizes precisely with your heartbeat. This is a known phenomenon in biventricular pacing due to the close proximity of the left ventricular lead in the coronary sinus to the diaphragmatic nerve. It can be easily corrected electronically in the clinic without requiring a new surgery.
- Fever: If you develop a fever above 38°C without any other obvious clinical cause.