Case History: The patient is a 74-year-old male with a medical history of coronary artery bypass grafting (CABG) and mitral valvuloplasty involving ring placement. The patient presented with atrial fibrillation and atrial flutter and had undergone an ablation procedure at another center 7 months prior. During that procedure, a severe hematoma developed in the right femoral region, necessitating hospitalization and blood transfusions. The patient was not provided with an operative report or discharge summary regarding that ablation procedure. Sinus rhythm was maintained for 5 months; however, a recurrence of atrial tachycardia occurred despite amiodarone therapy. The patient is now admitted to undergo an electrophysiological study and catheter ablation.
Transesophageal Echocardiogram: No thrombus was detected in the left atrium; only spontaneous echo contrast was observed.
Electrophysiological Study – Ablation:
Catheters:
- Quadripolar catheter positioned at the His bundle region and the right ventricle.
- Decapolar catheter positioned within the coronary sinus (CS).
- 20-polar circular mapping catheter for pulmonary vein (PV) mapping.
- 20-polar steerable tricuspid annulus mapping catheter (Duodecapolar, SJM-Abbott).
- Quadripolar steerable 3.5mm irrigated-tip ablation-mapping catheter, equipped with a TactiCath pressure sensor (St. Jude Medical).
- ViewFlex™ Xtra steerable intracardiac echocardiography (ICE) catheter (SJM-Abbott).
The NavX – Velocity system (St. Jude Medical) was utilized for the three-dimensional mapping of the left and right atria, and the EP Workmate Recording System (St. Jude Medical) was used for conventional recording and mapping.
Upon arrival at the electrophysiology laboratory, the patient was in atrial tachycardia with rapid ventricular response. The tachycardia exhibited a cycle length of 453 ms and an activation sequence presenting a relatively simultaneous recording across the CS dipoles, with a slight distal prematurity (AT1) (Recording 1).
At the initiation of the procedure and prior to performing the transseptal puncture, 6000 IU of unfractionated heparin were administered (total dose: 7000 IU).
Utilizing a transseptal sheath (Preface, Biosense Webster) and a BRK needle, transseptal puncture was performed at a central location of the fossa ovalis. The puncture of the fossa ovalis was carried out under echocardiographic guidance using the ViewFlex™ Xtra intracardiac ultrasound catheter (SJM-Abbott). Through the completed transseptal puncture, the ablation-mapping catheter was introduced into the left atrium, and via the transseptal sheath, the circular catheter was advanced into the left atrium for PV mapping.
Through sequential manipulation of the catheters, a three-dimensional model of the left atrium and the pulmonary veins was initially reconstructed. Electrograms were present in the left PVs, whereas relatively low-voltage potentials were recorded in the right PVs. The voltage map of the left atrium did not display extensive pathological low-voltage areas. During catheter manipulation, the tachycardia terminated due to mechanical ectopy, with subsequent restoration of sinus rhythm. Re-induction was performed, which elicited a second morphology of atrial tachycardia with a cycle length of 478 ms and a proximal-to-distal activation sequence in the CS (AT2) (Recording 2).
During this tachycardia, a local activation time (LAT) map was constructed in the left atrium, demonstrating a rapid centrifugal propagation of the impulse from the anterior aspect of the interatrial septum, a pattern potentially compatible with a right atrial origin of the tachycardia (Video 1). The 20-polar Duodecapolar catheter was introduced into the right atrium and positioned around the tricuspid annulus (Recordings 4, 5).
Similarly, an LAT map was constructed in the right atrium, which revealed an area of longitudinal scarring on the posterior wall and a reentrant circuit propagating in a caudo-cephalic direction along the lateral wall, which was refed by conduction through the mid-portion of the scar (Video 2, Figure 2).
During mapping of this tachycardia, a transition to AT1 occurred, which demonstrated a cephalo-caudal activation sequence along the lateral wall on the Duodecapolar catheter (Recording 3). This clearly represented a reversal of the wavefront direction within the same circuit in the right atrium (Figure 1). The CS activation sequence of AT1 could be explained by anterior conduction block at the scar tissue and the right atrial isthmus—the latter having evidently been ablated during the index procedure, as subsequently confirmed—and the propagation of the impulse from the posterior aspect of the left atrium (Video 3, Figure 1). Furthermore, the CS sequence remained identical during sinus rhythm (Recording 8). Additionally, during pacing from the anterolateral right atrial wall, the CS sequence was identical to that observed during AT2 (Recording 9).
Based on these findings, ablation was performed throughout the entire scar region where fragmented potentials were recorded. Prior to completing the lesions, a third morphology of atrial tachycardia (AT3) was induced by programmed stimulation, featuring a cycle length of 335 ms and a CS activation sequence similar to AT1. Evidently, AT3 was due to a smaller and faster circuit around the scar, with impulse propagation to the left atrium from its posterior wall (Figure 3). Delivery of ablation lesions within the scar area was performed during tachycardia (AT1) and resulted in its termination without any mechanical ectopy (Recording 7). After completing the application of lesions across the entire extent of the scar, re-induction was attempted, and no further tachycardia of any type could be elicited (Recordings 10, 11). Furthermore, pacing from the coronary sinus confirmed complete bidirectional block across the right atrial (cavotricuspid) isthmus line (Recording 12), which had evidently been created during the first operation.
The ECG presentation of these tachycardias is characteristic. In AT1, where propagation occurs from the posterior part of the left atrium, a positive P-wave is observed in lead V1 (Recording 13). Conversely, in AT2, where atrial excitation originates from the lateral wall of the right atrium, a negative P-wave is recorded in lead V1 (Recording 14, Video 4).
Postoperative Course: The procedure was uncomplicated. Anticoagulant therapy with rivaroxaban was initiated immediately. The patient was mobilized a few hours after the completion of the procedure.
Commentary: It is common for atrial tachycardias arising in patients who have undergone cardiac surgery to be associated with surgical incisions or cannulation scars in the atria. These frequently coexist with isthmus-dependent atrial flutter and can present either independently or concurrently with the isthmus-dependent circuit as a dual-loop (dual-wavelet) reentry tachycardia. Quite often, upon completion of the cavotricuspid isthmus line, the tachycardia degenerates into a scar-related circuit without necessarily causing a significant shift in the activation sequence on existing diagnostic catheters or even changing the tachycardia cycle length. This phenomenon likely led to extensive ablation at the right isthmus during the initial procedure (our mapping demonstrated a complete absence of voltages), without, however, achieving final ablation of all tachycardia circuits.
Additionally, the presence of scars acting as conduction blocks can generate unexpected electrophysiological and electrocardiographic recordings. Despite being a right atrial tachycardia, AT1 exhibited a distal-to-proximal activation sequence in the coronary sinus and a positive P-wave in lead V1.