Normal conduction of the impulse through the atrioventricular (AV) node is characterized by a 1:1 relationship between atrial and ventricular depolarization. However, in patients with dual electrophysiological behavior of the AV node (dual AV nodal pathways), a condition known as double ventricular response tachycardia can manifest under specific circumstances. This is a non-reentrant tachycardia that frequently mimics atrial fibrillation or atrial tachycardia clinically, thereby complicating the initial diagnosis. Elucidating its underlying mechanism is essential for selecting the appropriate invasive therapeutic approach.

Case History and Initial Evaluation

A 57-year-old male with an unremarkable medical history presented to our center due to reported palpitations, which exhibited progressive worsening and had become more pronounced over the recent period.

The resting electrocardiogram (ECG) demonstrated sinus rhythm. During the recording of tachycardic episodes, bursts of narrow-QRS tachycardia were observed, with a heart rate of approximately 160 beats per minute (~160 bpm) and prominent P waves displaying a morphology identical to that of sinus rhythm (high-to-low atrial depolarization) [Figures 1-2]. The patient was admitted to undergo an invasive electrophysiological study and catheter ablation.

Electrophysiological Study (EPS)

For the performance of the study, the following diagnostic catheters were utilized: a quadripolar catheter at the His bundle position, a quadripolar catheter in the high right atrium, a quadripolar catheter in the right ventricle, a decapolar catheter in the coronary sinus, the specialized high-definition Advisor™ HD Grid Mapping Catheter (Abbott), and a 4mm-tip steerable quadripolar ablation-mapping catheter (Abbott). The EnSite X (Abbott) system was employed for three-dimensional mapping.

Upon catheter insertion, a narrow-QRS tachycardia with a stable 1:2 P:QRS ratio was observed. The tachycardia demonstrated an R-R interval of 380–400 ms with a characteristic alternating cycle length (EP Recording 1).

The possibility of ventricular tachycardia was excluded, as the QRS complex was completely identical to the sinus-conducted beat and atrial depolarization was orthodromic (high-to-low). Furthermore, the relationship of the A wave to the subsequent QRS complex indicated stable conduction through the atrioventricular node. Consequently, the mechanism of double ventricular response (non-reentrant) tachycardia was confirmed, resulting from sequential conduction of the sinus impulse first via the fast and subsequently via the slow nodal pathway, thereby producing two QRS complexes for each single atrial impulse. The tachycardia was periodically interrupted by an echo beat, representing retrograde conduction of the impulse through the fast pathway (EP Recording 2).

Provocative & Pharmacological Testing

At baseline, under ventricular pacing at a cycle length of 500 ms, complete absence of ventriculoatrial (VA) conduction was observed (EP Recording 3).

Subsequent intravenous administration of isoproterenol led to the termination of the tachycardia and reinstatement of VA conduction. Despite this restoration, the induction of atrioventricular nodal reentrant tachycardia (AVNRT) could not be achieved by either ventricular or atrial extrastimulus pacing.

Differential Diagnosis from Nodal or Intra-Hisian Ectopy

The presence of nodal or intra-Hisian ectopy presenting as bigeminy was excluded with high precision via detailed mapping of impulse conduction through the His bundle. It was determined that the HV interval (His-ventricular time) remained completely equal and stable in both successive complexes (EP Recording 4). Concurrently, the use of the HD Grid multipolar high-definition catheter verified that conduction in both impulses was orthodromic and identical (EP Recording 5).

Ablation

Selective radiofrequency catheter ablation was performed in the region of the slow nodal pathway. During energy application, an accelerated junctional rhythm emerged, followed by the complete elimination of the tachycardia.

In the subsequent electrophysiological evaluation utilizing atrial extrastimulus pacing, persistence of the slow nodal pathway was noted but with a significantly shorter AH interval, without any capability of inducing AVNRT (EP Recordings 6-7). Following a waiting period of at least 25 minutes, the baseline tachycardia remained non-inducible.

Postoperative Course

The procedure was completed without any complications, and the patient remained in sinus rhythm for a sufficiently long period post-intervention.

Discussion

Double ventricular response tachycardia represents a highly uncommon etiology of palpitations. This specific case highlights the clinical value of detailed electrophysiological mapping.

Differential diagnosis from intra-Hisian longitudinal dissociation is critical, given that the latter involves anatomical splitting within the His bundle itself and carries a different risk profile for complications (e.g., complete atrioventricular block) during intervention. The stability of the HV interval across both QRS complexes (EP Recording 5), combined with the identical orthodromic activation sequence recorded by the high-definition HD Grid catheter (EP Recording 6), safely established the diagnosis of conduction via the slow nodal pathway. Modification or ablation of the slow pathway proved highly effective, providing a permanent cure and eliminating the patient’s arrhythmic burden.