Case History: The patient is a 59-year-old male with a medical history of prosthetic mitral valve replacement 7 years prior, presenting with symptomatic persistent atrial tachycardia. He was receiving oral anticoagulant therapy with acenocoumarol, which was not interrupted preoperatively, and was admitted for invasive management via catheter ablation.
Admission ECG: Regular atrial tachycardia with an atrial rate of 200 bpm and morphological features characteristic of typical atrial flutter, presenting with negative P-waves in the inferior leads.
Electrophysiological Study – Ablation:
Catheters:
- Quadripolar catheter positioned at the His bundle region and the right ventricle.
- Decapolar catheter positioned within the coronary sinus (CS).
- 20-polar tricuspid annulus mapping catheter (Duodecapolar, St. Jude Medical).
- Quadripolar steerable 8mm-tip ablation-mapping catheter.
The NavX – Velocity system (St. Jude Medical) was utilized for the three-dimensional mapping of the right atrium, and the EP Workmate Recording System (St. Jude Medical) was used for conventional recording and mapping.
Upon arrival at the electrophysiology laboratory, the patient presented in clinical tachycardia. The cycle length was 300 ms, with a proximal-to-distal activation sequence within the CS. Concurrently, the Duodecapolar catheter demonstrated a clockwise activation sequence, with a conduction block localized around the mid-portion of the right atrial lateral wall, likely attributable to a prior surgical scar (Recordings 1-2). Entrainment mapping was performed from three distinct sites along the right atrial isthmus (lateral, mid, and septal aspects). Entrainment was positive at all three sites, yielding a post-pacing interval (PPI) equal to the tachycardia cycle length (Recordings 3-5).
Ablation was performed to create a line across the right isthmus. Upon completion of this line—which was verified by the recording of widely spaced double potentials (150 ms) at the site of block—the arrhythmia transitioned into a slower atrial tachycardia with a prolonged cycle length of 373 ms (Recording 7).
Subsequently, activation mapping was conducted using the NavX system to construct a local activation time (LAT) map. Entrainment pacing was negative from the septal portion of the right isthmus (Recording 8) but remained positive from the lateral wall (Recordings 9, 10), while the activation sequence on the Duodecapolar catheter remained identical to that of the initial tachycardia. High-density mapping revealed a scar on the lateral wall and a clockwise reentrant circuit propagating around it. This scar-related circuit had likely coexisted with the cavotricuspid isthmus-dependent circuit as a double-loop reentry mechanism featuring a slower conduction velocity (Figure 1, Video).
During ablation, a lesion line was attempted to connect the scar to the superior vena cava (SVC), which successfully restored sinus rhythm (Recording 11). During sinus rhythm, the integrity of this lesion line was verified using pacing maneuvers; the cavotricuspid isthmus ablation line was similarly evaluated and confirmed to be intact (Recording 12).
Commentary: Following mitral valve surgery, surgical incisions performed on the atrial myocardium—in this specific case, within the right atrium—can establish the electrophysiological substrate necessary for reentrant circuits. The development of atrial tachycardias in this patient population should always prompt the inclusion of scar-related atrial tachycardias involving the myocardial wall in the differential diagnosis. Multiple reentrant circuits can coexist simultaneously; when this occurs, the circuit with the shorter cycle length typically becomes dominant and clinically manifest.